Leave Your Message
GCK Low Voltage Withdrawable Switchgear - Reliable Power Distribution Solutions by China Suppliers and Factory
Hot Products

GCK Low Voltage Withdrawable Switchgear - Reliable Power Distribution Solutions by China Suppliers and Factory

GCK low-voltage withdrawable switchgear, a top choice from China suppliers, is designed for three-phase four-wire and three-phase five-wire power systems operating at a frequency of 50Hz and rated voltage of 380V (400V). Suitable for rated currents of up to 4000A, this switchgear is extensively used in power plants, substations, industrial and mining enterprises, as well as in buildings, hotels, airports, and docks for efficient energy distribution, conversion, control, and reactive power compensation, Our switchgear serves dual functions as a power center (PC) and motor control center (MCC). It can be customized as a mixed fixed and withdrawable cabinet to cater to varied power supply and distribution requirements. Manufactured in our state-of-the-art factory, our GCK switchgear boasts high breaking capacity, excellent dynamic and thermal stability, innovative and reasonable design, a comprehensive range of electric solutions, and superior protection levels, making it an ideal replacement product for your electrical needs. Choose GCK low-voltage withdrawable switchgear for reliable performance and durability from trusted China suppliers

    Model meaning

    GCK Model meaning

    Conditions of use

    • Air temperature: The upper limit of ambient air temperature is +40℃, and the lower limit is -5℃. The average temperature within 24 hours should not exceed +35℃, the minimum temperature under storage and transportation conditions is -30℃.
    • Relative humidity: In clean air, it doesn't exceeds 50% at a maximum temperature of +40℃; higher relative humidity is allowable at lower temperatures (e.g. 90% at +20℃); however, it should be considered that occasional condensation may occur due to temperature change.
    • Installation location: When installing the equipment, the inclination of the vertical plane should not exceed 5°. It should be installed in a place without severe vibration and impact and with medium not enough to corrode electrical component.

    Product characteristics

    • Strong commonality of structure and flexible assembly: The switchgear is a fully assembled combination structure, with the basic framework assembled by FA steel. The outline dimension and opening dimension of the cabinet framework and components vary according to the basic modulus E=25mm.
    • The compartments of the switchgear can be divided into functional unit room, busbar room and cable room. The functions of each functional unit are relatively independent, and the areas are strictly separated by continuously grounded metal plate to ensure safe use and prevent the spread of accident.
    • All structural components inside the switchgear shall be galvanized and passivated. The door panels and side panels around the switchgear are made of high-quality cold-rolled steel plates processed and formed by CNC machine tool, and then the surface is treated with acid washing, phosphating, and electrostatic spraying for wear and corrosion resistance. It has both strong mechanical strength and reliable grounding protection continuity.
    • The draw-out unit of the switchgear has connection position, test position and disconnection position. Each draw-out unit and switch is equipped with mechanical interlock device: the draw-out unit can only be pulled out and inserted when the switch is in the open state, and cannot be pulled out or inserted when the switch is in the closed state. To prevent unauthorized operation, the operating mechanism handle can be locked in the open position with a padlock. Functional draw-out units of the same specification can be easily interchanged, with each draw-out unit corresponding to a maximum of 20 pairs of auxiliary contacts, which can meet the needs of remote operation control, electricity metering and computer interface automation monitoring system.

    Technical parameter

    Rated insulation voltage AC690V
    Rated working voltage AC380V(AC400V)
    Rated current of horizontal busbar 1250A, 1600A, 2000A, 3200A, 4000A
    Rated current of vertical busbar 1000A
    Maximum current of feeding circuit 2500A
    Maximum current of draw-out circuit 630A
    Maximum capacity of control motor 320kW
    Rated frequency 50Hz
    Peak withstand current of horizontal busbar 105kA, 176kA
    Short time withstand current of horizontal busbar(1s) 50kA, 80kA
    Peak withstand current of vertical busbar 63kA, 105kA
    Short time withstand current of vertical busbar(1s) 30kA, 50kA
    Rated power frequency withstand voltage(1min) 2500V
    Secondary power frequency withstand voltage(1min) 2500V
    Enclosure protection level IP40
    Enclosure dimension(mm) Width 600(800, 1000) × Depth 800(1000) × Height 2200
    Effective height of functional unit(mm) 1800

    Outline and installation dimension of switchgear

    Name of switchgear Width (W) Depth (D) Height (H)
    Incoming cabinet 600, 800, 1000 800, 1000 2200
    Bus-tie cabinet 600, 800, 1000
    Feeder cabinet 600, 800, 1000
    Draw-out cabinet 600, 800
    Compensation cabinet 600, 800, 1000
    Note: The above are recommended sizes. Users with special size requirements can negotiate with our company.
    Switchgear diagram 1
    Switchgear diagram 2
    Switchgear diagram 3

    GCK serial screen installation dimension

    Outline dimension(mm)   a b
    Width 600 480  
    800 680  
    Depth 1000 880  
    800   680
    1000   880
    GCK Installation Dimensions Diagram

    Frequently Asked Questions (FAQ)

    Q1: What are the ambient air temperature requirements for GCK switchgear?

    The ambient air temperature must have an upper limit of +40℃ and a lower limit of -5℃. Additionally, the average temperature within a 24-hour period should not exceed +35℃, and the storage or transportation temperature can go as low as -30℃.

    Q2: What is the enclosure protection level of this switchgear?

    The standard enclosure protection rating for the GCK switchgear is IP40, which ensures effective shielding against solid foreign objects greater than 1mm.

    Q3: How does the mechanical interlock device work in the draw-out unit?

    The draw-out unit includes connection, test, and disconnection positions. The built-in mechanical interlock ensures safety by only allowing the unit to be inserted or pulled out when the switch is in the open state. It remains locked and cannot be moved when the switch is closed.

    Q4: Can the dimensions of the GCK switchgear cabinet be customized?

    Yes. While standard configurations recommend widths of 600, 800, or 1000mm, depths of 800 or 1000mm, and a height of 2200mm, users with special size requirements can negotiate customization with our company.

    Q5: What anti-corrosion treatments are applied to the switchgear components?

    All internal structural parts are galvanized and passivated. The door and side panels are made of high-quality cold-rolled steel plates processed by CNC machines, followed by acid washing, phosphating, and electrostatic spraying for maximum wear and corrosion resistance.