Introducing the DSR6-12/24/40.5 series of SF6 Gas Insulated Metal Enclosed Switchgear (C-GIS), a cutting-edge solution independently developed by our company, designed to serve both primary and secondary power distribution needs. Utilizing sulphur hexafluoride gas as the insulating medium, this new-generation medium-voltage switchgear incorporates advanced technologies such as vacuum arc extinguishing, APG solid sealing, gas insulation, and interface insulation, Manufactured in our state-of-the-art factory, this product features a modular design, allowing for versatile combinations based on specific design requirements. With a sealed pressure system, all high-voltage live components are securely housed within a stainless steel gas tank, ensuring reliable operation unaffected by environmental conditions. The compact design minimizes space requirements while offering maintenance-free performance, making it an ideal choice for power distribution applications, Choose us as your trusted supplier in China for innovative and reliable SF6 Gas Insulated Switchgear, and experience the benefits of advanced technology and superior engineering

    Model and meaning
    Model and meaning diagram
    Work environment
    • Altitude ≤ 5000m (when it runs at an altitude over 1000m, pay special attention).
    • Ambient temperature: highest +50°C, lowest -25°C, 24h average ≤ 35°C.
    • Ambient humidity: 24h relative humidity average ≤ 95%; monthly relative humidity average ≤ 90%.
    • Electromagnetic interference: the amplitude of electromagnetic interference induced in the secondary system ≤ 1.6kV.
    • Installation environment: no explosive or corrosive gas in ambient environments, no frequent violent vibration or shock in the area to install. Note: for any deviation from these ambient environment conditions above, consult with the company to customize.
    Work environment specifications
    Main technical parameters

    Item

    Unit

    Parameter

    Rated voltage

    kV

    12

    24

    40.5

    Rated frequency

    Hz

    50

    Rated current

    A

    630/1250/2500/3150/4000

    630/1250/2500

    Rated insulation level

    Power frequency withstand voltage (phase-to-phase and phase-to-ground)

    kV

    42

    65

    95

    Power frequency withstand voltage (insulation breaking)

     

    48

    79

    118

    Lightning impulse withstand voltage (phase-to-phase and phase-to-ground)

    kV

    75

    125

    185

    Lightning impulse withstand voltage (insulation breaking)

    kV

    85

    145

    215

    Rated power frequency withstand voltage of auxiliary circuit

    kV

    2

    Rated instantaneous withstand current

    kA

    25/31.5/40

    Rated short-circuit period

    s

    3

    Rated peak withstand current

    kA

    63/80/100

    63/80/100

    50/63/80

    Rated short-circuit breaking current of circuit breaker

    kA

    25/31.5/40

    25/31.5/40

    25/31.5

    Rated short-circuit closing current of circuit breaker (peak)

    kA

    63/80/100

    63/80/100

    50/63/80

    Rated cable charge breaking current

    A

    25

    Rated operating sequence

     

    0-0.3s-CO-3min-CO

    Insulation gas

     

     

    SF6

    Mechanical life

    Circuit breaker

    Time

    10000

    Three-position switch

    Time

    5000

    SF6 gas rated pressure (abs.20°C)

    Rated charge pressure (abs, 20°C)

    Mpa

    0.14

    Minimum charge pressure (abs, 20°C)

    Mpa

    0.12

    Protection grade

    Sealed enclosure

    Grade

    IP67

    Switchgear shell

    Grade

    UP4X

    Annual relative leak rate of dry air

    %/year

    ≤0.1

    Rated power voltage of auxiliary circuit

    V

    DC48/110/220 AC220

    The general external dimensions of switchgears

    Rated voltage (kV)

    Main bus rated current (A)

    Type of cabinet

    a (mm) Width

    b (mm) Depth

    d (mm) Height

    Remark

    12/24/40.5

    630/1250

    Incoming, sectional, insulated, outgoing

    600

    1600

    2400

    PT tertiary

    (PT) Bus (PT)

    1000

    Metering cabinet

    Gas tank

    600/1000

    According to voltage transformer

    Air

    2500/3150/4000

    Incoming, sectional, insulated, outgoing Bus (PT)

    800/1000

    1800

    2400

    PT tertiary

    Min technical parameters

    NO.

    Scheme

    Description

    Function

    1

    Scheme 1

    Cable feeder cabinet
    1 lower incoming
    1 upper incoming

    With three-position switch, circuit breaker, closing and breaking cable and bus, can close and break the rated current; the bus on both sides can expand. In the circuit breaker gas chamber, 3 female sockets are reserved to plug in/out the plug-in cable; the arrester, potential transformer and the unused sockets can be blocked. The cable has upper incoming or lower incoming. Can cancel or block the grounding switch.

    2

    Scheme 2

    Sectional circuit breaker cabinet
    1 left link
    1 right link

    With three-position switch, combined the sectional circuit breaker cabinet, to sectionalize and link the bus; can cancel or block the grounding switch.

    3

    Scheme 3

    Sectional insulation cabinet
    1 left link
    1 right link

    With three-position switch, combined with sectional circuit breaker cabinet, to sectionalize and link the bus; can cancel or block the grounding switch.

    Main technical parameters

    NO.

    Scheme

    Description

    Function

    4

    Scheme 4

    Insulation upgraded cabinet
    1 lower incoming
    1 upper incoming

    With three-position switch, connect or insulate cable and bus; the bus on both sides can expand. Can cancel or block the grounding switch if grounding isn't required.

    5

    Scheme 5

    Insulation cabinet

    With three-position switch, female socket is reserved in the gas tank to plug in the plug-in arrester and potential transformer.

    6

    Scheme 6

    Metering cabinet

    With built-in current transformer and plug-in potential transformer, it can be combined with other functional units.

    7

    Scheme 7

    Main bus grounding cabinet
    1 left link
    1 right link

    With grounding switch, ground the main bus; usually the bus on one side can expand to connect with the main buses of other functional units.

    Main technical parameters

    NO.

    Scheme

    Description

    Function

    8

    Scheme 8

    Cable incoming/outgoing cabinet (for non-separable structure of gas tank)

    With three-position switch, circuit breaker, grounding and breaking cable and bus, can close or break the rated current, the bus on both sides can expand. On the bus side, can plug in/out the plug-in arrester or potential transformer and the unused sockets can be blocked. Can cancel or block the grounding switch if grounding isn’t required.

    9

    Scheme 9

    Sectional+insulation cabinet
    -sectional circuit breaker cabinet and
    sectional insulation cabinet combined

    With three-position switch, circuit breaker and built-in current transformer, to sectionalize and link the bus. Can cancel or block the grounding switch if grounding isn’t required.

    Note: These functional modular units above are available for OEM partners.

    Model number: Add rated voltage and branch bus rated current into the model number of the gas tank. If the main bus rated current and the branch bus rated current are different, indicate in the brackets.

    For example:

    XGN(DSR6) -12/1250: 12kV switchgear, branch bus, main bus rated current is 1250A;

    XGN(DSR6) -12/1250 (2500): 12kV switchgear, branch bus rated current is 1250A, main bus rated current is 2500A;

    Frequently Asked Questions (FAQ)
    Q: What are the environmental limits for installing this switchgear?
    The switchgear is designed for altitudes up to 5000m (with special attention above 1000m), temperatures from -25°C to +50°C, and relative humidity up to 95% (24h average). The installation site must be free of explosive or corrosive gases and severe vibrations.
    Q: What is the mechanical lifespan of the circuit breaker and three-position switch?
    The circuit breaker has a rated mechanical life of 10,000 operations, while the three-position switch is rated for 5,000 operations.
    Q: What type of insulation gas is used in the system?
    The switchgear utilizes SF6 (Sulfur Hexafluoride) gas as its primary insulation medium.
    Q: What are the ingress protection (IP) ratings for this product?
    The sealed enclosure features an IP67 protection grade, and the external switchgear shell features a UP4X protection grade.
    Q: Are the modular units customizable for OEM partners?
    Yes, all the functional modular units described (including cable feeder, sectional circuit breaker, insulation, and metering cabinets) are available for OEM partners.
    Q: How should I read the model numbering system?