35KV 630A Deadbreak T Rear Connector - Reliable China Supplier & Factory for High-Quality Connectors
35KV 630A European After Connector
General: 630A European after connector can be use together with the T Fore connector and some other back connector, it can be provide more branches, and they can not together with the bushing directly, cover the back protection cap on the end of the blanking cover.
Key Features
- Provides a fully screened and fully submersible separable connection when mated with the proper bushing or plug.
- Can be used under the circumstances.
- Built-in capacitive test point to determine the circuit status or install a fault indicator.
- No minimum phase clearance requirements.
- Mounting can be vertical, horizontal, or any angle in between.
Scope of Delivery
630A European after connector
Adaptor
Conductor cable lug
Connect lug
Two head screw
Silicone Lubricant
Clearing Paper
Installation Instruction Sheet
Quality Certificate
| Reference No. | Conductor cross section (mm²) | Stretch range over insulation (mm) | Cable Type | Size of Stress Cone |
|---|---|---|---|---|
| DR HTT-35/630-50 | 50 | 31 | 26/35 | A |
| DR HTT-35/630-70 | 70 | 32.6 | 26/35 | B |
| DR HTT-35/630-95 | 95 | 34.2 | 26/35 | C |
| DR HTT-35/630-120 | 120 | 35.6 | 26/35 | C |
| DR HTT-35/630-150 | 150 | 37.2 | 26/35 | D |
| DR HTT-35/630-185 | 185 | 38.7 | 26/35 | E |
| DR HTT-35/630-240 | 240 | 41.1 | 26/35 | F |
| DR HTT-35/630-300 | 300 | 43.2 | 26/35 | G |
| DR HTT-35/630-400 | 400 | 46.4 | 26/35 | H |
| DR HTT-35/630-500 | 500 | 49.2 | 26/35 | I |
| DR HTT-35/630-630 | 630 | 52.5 | 26/35 | I |
Frequently Asked Questions
Can the 630A European after connector be connected directly to the bushing?
No, they cannot be connected directly with the bushing. They must be used together with the T Fore connector or another back connector, and you should cover the back protection cap on the end of the blanking cover.
What mounting angles are supported for this connector?
The connector features flexible mounting configurations and can be installed vertically, horizontally, or at any angle in between to fit your specific space requirements.
What is the function of the built-in capacitive test point?
The built-in capacitive test point is designed to easily determine the circuit status or to facilitate the installation of a fault indicator.
Does this European after connector require a minimum phase clearance?
No, there are no minimum phase clearance requirements for installing this separable connector.
What is included in the standard scope of delivery?
The standard package includes the 630A European after connector, Adaptor, Conductor cable lug, Connect lug, Two head screw, Silicone Lubricant, Clearing Paper, Installation Instruction Sheet, and a Quality Certificate.