High-Voltage AC Metal Fixed Switchgear XGN□-12(40.from China Suppliers | Reliable Factory Solutions
Model meaning
Conditions of use
-
Altitude: ≤1000m
-
Ambient temperature: upper limit +40℃, lower limit -15℃
-
Ambient humidity: daily average shall not exceed 95%, monthly average shall not exceed 90%
-
Seismic intensity: ≤8 degrees
-
Air quality: The ambient air should not be contaminated by corrosive and flammable gas or water vapor
-
Vibration: In places without frequent severe vibration
Product characteristics
-
The cabinet is welded with high-quality angle steel.
-
The appearance design of this switchgear is beautiful, the appearance quality is good, the internal structure is compact, the layout is scientific and reasonable, and it is easy to maintain.
-
The cabinet adopts air insulation, with metal partitions between different compartments. Each compartment has an independent pressure relief channel, ensuring reliable protection and safe maintenance.
-
The VS1-12(ZN12-40.5) vacuum circuit breaker matched with this cabinet is fixedly installed, with stable performance, reliable operation, high design parameters and good interlocking function with the switchgear.
-
The improved GN30-12(GN27-35) series with ground knife isolation switch used in this cabinet is designed scientifically and reasonably, with flexible operation and reliable program.
-
The locking mechanism of the operating mechanism adopts improved GTXGN.12 (JSXGN-35) interlocking mechanism, which is simple, reliable, convenient and practical. The "five prevention" function of this cabinet has achieved perfect effect, ensuring the safety and reliability of its maintenance.
Product structure drawing
Technical parameter (40.5kV)
| Item | Unit | Argument |
|---|---|---|
| Rated voltage | kV | 40.5 |
| Rated frequency | Hz | 50 |
| Rated current | A | 630、1250、1600、2000 |
| Power frequency withstand voltage of primary main circuit 1min | kV | 95 |
| Power frequency withstand voltage of control circuit | V | 2000 |
| Lightning impulse withstand voltage | kV | 185 |
| Rated breaking current(effective value) | kA | 25、31.5 |
| Rated making current(peak value) | kA | 63、80 |
| Rated dynamic stability current(peak value) | kA | 63、80 |
| Rated 4s thermal stability current (effective value) | kA | 25、31.5 |
| Rated voltage of auxiliary control circuit | V | DC110、DC220、AC110、AC220 |
| Protection level | IP2X | |
| Outline dimension(Width×Depth×Height) | mm | 1818×3100×3200 |
Technical parameter (12kV)
| Rated voltage | Unit | Argument |
|---|---|---|
| Rated frequency | kV | 12 |
| Rated current | Hz | 50 |
| Power frequency withstand voltage of primary main circuit 1min | A | 630、1250、1600、2000 |
| Power frequency withstand voltage of control circuit | kV | 42 |
| Lightning impulse withstand voltage | V | 200 |
| Rated breaking current(effective value) | kV | 75 |
| Rated making current(peak value) | kA | 25、31.5 |
| Rated dynamic stability current(peak value) | kA | 63、80 |
| Rated 4s thermal stability current(effective value) | kA | 63、80 |
| Rated voltage of auxiliary control circuit | kA | 25、31.5 |
| Protection level | V | DC110、DC220、AC110、AC220 |
| Outline dimension(Width×Depth×Height) | IP2X | |
| Outline dimension(Width×Depth×Height) | mm | 900×1000×2300 |
Frequently Asked Questions
What are the environmental requirements for using this switchgear?
The switchgear is designed for altitudes ≤1000m, ambient temperatures between -15℃ and +40℃, and relative humidity not exceeding 95% (daily average) or 90% (monthly average). It should be installed in environments without frequent severe vibration and free from corrosive or flammable gas.
What type of circuit breaker is used in this cabinet?
It is matched with a fixed-installation VS1-12(ZN12-40.5) vacuum circuit breaker, which offers stable performance, reliable operation, and a robust interlocking function with the switchgear.
How does the cabinet design ensure safety during maintenance?
The cabinet utilizes air insulation with metal partitions separating the compartments. Each compartment has an independent pressure relief channel to ensure safety. Additionally, the improved GTXGN.12 (JSXGN-35) interlocking mechanism provides a complete "five prevention" safety function.
What is the protection level of this switchgear?
Both the 12kV and 40.5kV variants of this switchgear cabinet are designed to meet the IP2X protection rating.
What are the dimensions of the switchgear cabinets?
The outline dimensions (Width×Depth×Height) are 1818×3100×3200 mm for the 40.5kV model and 900×1000×2300 mm for the 12kV model.