Leave Your Message
GCS Low voltage withdrawable type switchgear
Products

GCS Low voltage withdrawable type switchgear

GCS type low-voltage withdrawable switchgear(hereinafter referred to as the switchgear)is a new product that was not successfully designed and

developed by the joint design team of the former Ministry of Electric Power Industry and the Ministry of Machinery Industry in the 1990s.It is in line with the

national conditions,has high technical performance,can adapt to the needs of the development of the electricity market,and can compete with existing

imported products,so that it has been highly valued and selected by a large number of electricity users.This switchgear is suitable for three-phase four-wire and three-phase five-wire power system with frequency of three-phase AC 50Hz,rated voltage of 380V(400V),rated current of 4000A and below.It's widely used by power plants,substations,industrial and mining enterprises,buildings,hotels,airports,docks and other electricity users for energy distribution,

conversion,control and reactive power compensation,it includes the functions of power center(PC)and motor control center(MCC),and can be designed as mixed fixed and withdrawable cabinet to meet different power supply and distribution needs.The switchgear has the characteristics of high breaking capacity,good dynamic and thermal stability,novel and reasonable structure,complete electric solution series,and high protection level,making it an ideal replacement product.

    Model meaning

    20241106-德锐电气(2024版)(中英文)最终定稿版-70.jpg

    Conditions of use

    ◆Altitude:≤2000m;

    ◆Air temperature:The upper limit of ambient air temperature is+40℃,and the lower limit is-5℃.The average temperature within 24 hours should not exceed+35℃,the minimum temperature under storage and transportation conditions is-30℃.

    ◆Relative humidity:it doesn't exceeds 50%at a maximum temperature of+40℃;higher relative humidity is allowable at lower temperatures(e.g.90% at +20℃);however,it should be considered that occasional condensation may occur due to temperature change.

    ◆Installation location: When installing the equipment,the inclination of the vertical plane should not exceed 5°. It should be installed in a place without severe vibration and impact and with medium not enough to corrode electrical component.

    ◆Note:; When the above normal service conditions cannot meet the usage requirement, it shall be negotiated between the user and the manufacturer.

    Product characteristics

    ◆Strong commonality of structure and flexible assembly: The switchgear is a fully assembled combination structure, with installation holes of 20mm and 100mm modules on the side, with diameter of φ 9.2mm, making internal installation flexible and convenient.

    ◆The compartments of the switchgear can be divided into functional unit room,busbar room and cable room, The functions of each functional unit are relatively independent, and the areas are strictly separated by continuously grounded metal plate or pressed flame-retardant plastic plate to ensure safe use and prevent the spread of accident.

    ◆All structural components inside the switchgear shall be galvanized and passivated. The door panels and side panels around the switchgear are made of high-quality cold-rolled steel plates processed and formed by CNC machine tool, and then the surface is treated with acid washing, phosphating, and electrostatic spraying for wear and corrosion resistance,It has both strong mechanical strength and reliable grounding protection continuity.

    ◆The draw-out unit of the switchgear has connection position, test position,disconnection position,draw-out position and isolation position. Each draw-out unit and switch is equipped with mechanical interlock device: the draw-out unit can only be pulled out and inserted when the switch is in the open state, and cannot be pulled out or inserted when the switch is in the closed state. To prevent unauthorized operation,the operating mechanism handle can be locked in the open position with a padlock, Functional draw-out units of the same specification can be easily interchanged, with each draw-out unit corresponding to a maximum of 36 pairs of auxiliary contacts, which can meet the needs of remote operation control. electricity metering and computer interface automation monitoring system.

    ◆The horizontal main busbar is flatly arranged at the back of cabinet to enhance the busbar's ability to resist electric power, which is a basic measure to make the main circuit of the device have high short-circuit strength, The vertical busbar is assembled in insulated functional board to prevent phase discharge caused by switch arcing on the vertical busbar,improving the product's electric shock protection ability and safe operation rate. The design of the cable compartment makes it very convenient for cables to enter and exit both up and down.

    Technical parameter

    Rated insulation voltage (V)

    AC660

    Rated working voltage(V)

    AC380V(AC400)

    Rated current of horizontal busbar(A)

    ≤4000A

    Rated current of vertical busbar(A)

    1000A

    Maximum current of draw-out circuit(A)

    400A

    Rated frequency(Hz)

    50(60)

    Peak withstand current of horizontal busbar(kA)

    105,176

    Short time withstand current of horizontal busbar(kA/1S)

    50,80

    Peak withstand current of vertical busbar(kA)

    105

    Short time withstand current of vertical busbar(kA/1S)

    50

    Rated power frequency withstand voltage(V/1min)

    2500

    Secondary power frequency withstand voltage(V/1min)

    2500

    Enclosure protection level

    IP40

    Enclosure dimension(mm)

    Width 600(800,1000)×Depth 800(1000)×Height 2200

    Effective height of functional unit(mm)

    1760

    Switchgear and draw-out types

    According to the purpose,it can be classified into:incoming cabinet,bus-tie cabinet,feeder cabinet(motor centralized control cabinet,lighting distribution cabinet),and reactive power compensation cabinet.According to the incoming method,it can be classified into four types:upper incoming and upper outgoing,upper incoming and lower outgoing,lower incoming and upper outgoing,and lower incoming and lower outgoing.

    There are five specifications for draw-out unit height,all based on a unit height of 160mm:1/2 unit,1 unit,3/2 unit,2 unit and 3 unit in five sizes.Draw-out circuit current is 400A or below.

    Outline and installation dimension of switchgear

    Name of switchgear

    Width(W)

    Depth(D)

    Height(H)

    Cable outlet(FXG)

    Incoming cabinet

    600、800、1000

    800、1000

    2200

     

    Bus-tie cabinet

    800、1000

     

    Feeder cabinet

    800、1000

    200×400、400×400

    Draw-out cabinet

    800、1000

    200×350、400×350

    Compensation cabinet

    800、1000

     

    Note:The above are recommended sizes.Users with special size requirement can negotiate with our company

    20241106-德锐电气(2024版)(中英文)最终定稿版-71.jpg20241106-德锐电气(2024版)(中英文)最终定稿版-71-1.jpg

    Mounting dimension

    20241106-德锐电气(2024版)(中英文)最终定稿版-72.jpg

    Installation diagram

    20241106-德锐电气(2024版)(中英文)最终定稿版-72-1.jpg