Cast Resin Dry Type Transformers from China | Safe, Maintenance-Free Solutions by Trusted Suppliers & Factory
Application
SC(B)10 & SC(B)11 & SC(B)111 series three phase resin-cast dry-type distribution transformer are in conformity with standard of IEC60076 with features of low loss, compact and light weight, low noise level, clamp-proof, anti-fouling, high mechanical strength, flame resisting, strong overload ability and low partial discharge quality, they are application to power transmission and distribution system, hotel, restaurant, commercial building, stadiums, chemical plants, stations, airports, offshore drilling platforms, especially to heavy load centers and places with fire protection requirements.
Product Range
Transformer Capacity
10kVA through 100MVA
Temperature Rise
100℃
Cooling Type
AN & AN/AF
Three Phase Frequency
50/60HZ
Primary Voltage
6kV through 40.5KV
Secondary Voltage
380V & 400V & 415V & 433V or other
Technical Specification
| Type | Voltage combination | Vector group |
Loss(W) | Imped- ance % |
Dimension (L*W*H) mm |
Weight (kg) |
|||
|---|---|---|---|---|---|---|---|---|---|
| Primary (kV) |
Tapping range |
Secondary (kV) |
NO Load |
Full Load |
|||||
| SC(B)11-30/10 | 6 | ±2x2.5% | 0.4 or other |
Yyn0 or Dyn11 |
171 | 665 | 4.0 | 680*400*686 | 300 |
| SC(B)11-50/10 | 6.6 | 243 | 941 | 690*400*686 | 360 | ||||
| SC(B)11-80/10 | 7.2 | 324 | 1302 | 730*450*796 | 500 | ||||
| SC(B)11-100/10 | 10 or 11 or 13.8 or 15 or 20 or 22 or 24 or 30 or 33 or 36 |
360 | 1492 | 730*500*816 | 600 | ||||
| SC(B)11-125/10 | 423 | 1748 | 780*600*950 | 700 | |||||
| SC(B)11-160/10 | 486 | 2014 | 950*650*1124 | 850 | |||||
| SC(B)11-200/10 | 558 | 2394 | 990*650*1207 | 950 | |||||
| SC(B)11-250/10 | 648 | 2613 | 1020*650*1207 | 1100 | |||||
| SC(B)11-315/10 | 792 | 3287 | 1050*750*1320 | 1250 | |||||
| SC(B)11-400/10 | 873 | 3781 | 1100*800*1450 | 1550 | |||||
| SC(B)11-500/10 | 1044 | 4636 | 1140*800*1430 | 1850 | |||||
| SC(B)11-630/10 | 1206 | 5577 | 1250*800*1500 | 1900 | |||||
| SC(B)11-800/10 | 1368 | 6603 | 1330*800*1540 | 2200 | |||||
| SC(B)11-1000/10 | 1584 | 7714 | 1400*960*1640 | 2750 | |||||
| SC(B)11-1250/10 | 1881 | 9206 | 6.0 | 1450*960*1690 | 3300 | ||||
| SC(B)11-1600/10 | 2205 | 11144 | 1560*960*1930 | 4000 | |||||
| SC(B)11-2000/10 | 2988 | 13728 | 1680*960*1930 | 4800 | |||||
| SC(B)11-2500/10 | 3240 | 16312 | 1720*1010*1950 | 5500 | |||||
Note: The above parameters are only the parameters of some transformers listed by our company. Any transformer capacity can be customized. (special requirement can be customized.)
Frequently Asked Questions
Q1: What standards do the SC(B)10, SC(B)11, and SC(B)111 series transformers conform to?
A1: These three-phase resin-cast dry-type distribution transformers are built in full conformity with the international IEC60076 standard.
Q2: What are the main features of these dry-type distribution transformers?
A2: Key features include low loss, compact and light weight, low noise level, clamp-proof, anti-fouling, high mechanical strength, flame resisting, strong overload ability, and low partial discharge quality.
Q3: Where are these transformers typically applied?
A3: They are widely applied in power transmission and distribution systems, hotels, restaurants, commercial buildings, stadiums, chemical plants, stations, airports, offshore drilling platforms, and especially heavy load centers and areas with strict fire protection requirements.
Q4: What is the available product range for capacity and voltage?
A4: The capacity ranges from 10kVA through 100MVA. The primary voltage ranges from 6kV through 40.5KV, while the secondary voltage options include 380V, 400V, 415V, 433V, or other specifications.
Q5: What cooling types and temperature rise limits do they support?
A5: They support AN (Air Natural) & AN/AF (Air Natural/Air Forced) cooling types, with a standard temperature rise limit of 100℃.
Q6: Can these distribution transformers be customized?
A6: Yes, the technical parameters listed in the specification table represent only a portion of our product line. Any transformer capacity and special requirements can be fully customized to meet your specific application needs.