15KV 630A Deadbreak T Rear Connector - High Quality China Suppliers and Factory for Reliable Electric Solutions
15KV 630A European after connector. General 630A European after connector can be use together with the T Fore connector and some other back connector, it can be provide more branches, and they can not together with the bushing directly, cover the back protection cap on the end of the blanking cover.
- Provides a fully screened and fully submersible separable connection when mated with the proper bushing or plug.
- Can be used under the circumstances.
- Built-in capacitive test point to determine the circuit status or install a fault indicator.
- No minimum phase clearance requirements.
- Mounting can be vertical, horizontal, or any angle in between.
- Two head screw
- Insulation
- Insulating plug
- Semi-conductive insert
- Stress relief
- Grounding eye
- Semi-conductive shield
- Conductor cable lug
- 630A European after connector
- Adaptor
- Conductor cable lug
- Connect lug
- Two head screw
- Silicone Lubricant
- Clearing Paper
- Installation Instruction Sheet
- Quality Certificate
| Reference No. | Conductor cross section (mm²) | Stretch range over insulation (mm) | Cable Type | Size of stress cone |
|---|---|---|---|---|
| DR JBK-15/630-25 | 25 | 16.6 | 8.7/15 | A |
| DR JBK-15/630-35 | 35 | 17.6 | 8.7/15 | A |
| DR JBK-15/630-50 | 50 | 19 | 8.7/15 | A |
| DR JBK-15/630-70 | 70 | 20.6 | 8.7/15 | B |
| DR JBK-15/630-95 | 95 | 22.2 | 8.7/15 | B |
| DR JBK-15/630-120 | 120 | 23.6 | 8.7/15 | C |
| DR JBK-15/630-150 | 150 | 25.2 | 8.7/15 | C |
| DR JBK-15/630-185 | 185 | 26.7 | 8.7/15 | D |
| DR JBK-15/630-240 | 240 | 29 | 8.7/15 | D |
| DR JBK-15/630-300 | 300 | 31.2 | 8.7/15 | E |
| DR JBK-15/630-400 | 400 | 34.4 | 8.7/15 | E |
| DR JBK-15/630-500 | 500 | 37.2 | 8.7/15 | F |
| DR JBK-15/630-630 | 630 | 40.5 | 8.7/15 | G |
Q: How can the 15KV 630A European after connector be used to expand branches?
A: It can be used together with the T Fore connector and other back connectors to provide more branches in the electrical connection system.
Q: Can this connector be directly connected with the bushing?
A: No, they cannot be connected together with the bushing directly. You must cover the back protection cap on the end of the blanking cover.
Q: What mounting angles are supported for installation?
A: The mounting can be vertical, horizontal, or set at any angle in between, allowing for flexible installation designs.
Q: Does the installation require a minimum phase clearance?
A: No, there are no minimum phase clearance requirements for this European after connector.
Q: What is the function of the built-in capacitive test point?
A: The built-in capacitive test point is designed to determine the circuit status or to facilitate the installation of a fault indicator.
Q: What items are included in the standard Scope of Delivery?
A: The scope of delivery includes the 630A European after connector, Adaptor, Conductor cable lug, Connect lug, Two head screw, Silicone Lubricant, Clearing Paper, Installation Instruction Sheet, and a Quality Certificate.