China DSR6-12/24/40.5 SF6 Gas Insulated Metal Enclosed Switchgear - Reliable Suppliers & Factory Solutions
Hot Products

China DSR6-12/24/40.5 SF6 Gas Insulated Metal Enclosed Switchgear - Reliable Suppliers & Factory Solutions

Introducing the DSR6-12/24/40.5 series of SF6 Gas Insulated Metal Enclosed Switchgear (C-GIS), a cutting-edge solution independently developed by our factory in China. Utilizing sulphur hexafluoride gas as the insulating medium, this advanced switchgear is designed for both primary and secondary power distribution applications, Our product integrates state-of-the-art technologies, including vacuum arc extinguishing, APG solid sealing, gas insulation, and interface insulation, making it a reliable choice for medium-voltage power systems. The modular design allows for flexible combinations based on various design requirements, ensuring versatility for our clients, The DSR6 series features a sealed pressure system, with all high-voltage live components securely housed in a stainless steel gas tank, offering protection from environmental influences. This switchgear operates with high reliability, occupies minimal space, and requires no maintenance, setting a new standard in the industry, As leading suppliers in the market, we are committed to providing innovative and effective solutions that meet the demands of modern electrical infrastructure

    Model and meaning
    20241106-德锐电气(2024版)(中英文)最终定稿版-13.jpg
    Work environment
    ◆

    Altitude ≤ 5000m (when it runs at an altitude over 1000m, pay special attention).

    ◆

    Ambient temperature: highest +50°C, lowest -25°C, 24h average ≤ 35°C.

    ◆

    Ambient humidity: 24h relative humidity average ≤ 95%; monthly relative humidity average ≤ 90%.

    ◆

    Electromagnetic interference: the amplitude of electromagnetic interference induced in the secondary system ≤ 1.6kV.

    ◆

    Installation environment: no explosive or corrosive gas in ambient environments, no frequent violent vibration or shock in the area to install. Note: for any deviation from these ambient environment conditions above, consult with the company to customize.

    20241106-德锐电气(2024版)(中英文)最终定稿版-14..jpg
    Main technical parameters

    Item

    Unit

    Parameter

    Rated voltage

    kV

    12

    24

    40.5

    Rated frequency

    Hz

    50

    Rated current

    A

    630/1250/2500/3150/4000

    630/1250/2500

    Rated insulation level

    Power frequency withstand voltage(phase- to-phase and phase-to-ground)

    kV

    42

    65

    95

    Power frequency withstand voltage(insulation breaking)

     

    48

    79

    118

    Lightning impulse withstand voltage (phase-to-phase and phase-to-ground)

    kV

    75

    125

    185

    Lightning impulse withstand voltage(insulation breaking)

    kV

    85

    145

    215

    Rated power frequency withstand voltage of auxiliary circuit

    kV

    2

    Rated instantaneous withstand current

    kA

    25/31.5/40

    Rated short-circuit period

    s

    3

    Rated peak withstand current

    kA

    63/80/100

    63/80/100

    50/63/80

    Rated short-circuit breaking current of circuit breaker

    kA

    25/31.5/40

    25/31.5/40

    25/31.5

    Rated short-circuit closing current of circuit breaker(peak)

    kA

    63/80/100

    63/80/100

    50/63/80

    Rated cable charge breaking current

    A

    25

    Rated operating sequence

     

    0-0.3s-CO-3min-CO

    Insulation gas

     

     

    SF6

    Mechanical life

    Circuit breaker

    Time

    10000

    Three-position switch

    Time

    5000

    SF6 gas rated pressure (abs.20℃)

    Rated charge pressure(abs,20℃)

    Mpa

    0.14

    Minimum charge pressure(abs,20℃)

    Mpa

    0.12

    Protection grade

    Sealed enclosure

    Grade

    IP67

    Switchgear shell

    Grade

    UP4X

    Annual relative leak rate of dry air

    %/year

    ≤0.1

    Rated power voltage of auxiliary circuit

    V

    DC48/110/220 AC220

    The general external dimensions of switchgears

    Rated voltage (kV)

    Main bus rated current(A)

    Type of cabinet

    a (mm) Width

    b (mm) Depth

    d (mm) Height

    Remark

    12/24/40.5

    630/1250

    Incoming, sectional, insulated, outgoing

    600

    1600

    2400

    PT tertiary

    (PT)Bus(PT)

    1000

    Metering cabinet

    Gas tank

    600/1000

    According to voltage transformer

    Air

    2500/3150/4000

    Incoming, sectional, insulated, outgoing Bus(PT)

    800/1000

    1800

    2400

    PT tertiary

    Min technical parameters

    NO.

    Scheme

    Description

    Function

    1

    图片2.jpg

    Cable feeder cabinet
    1 lower incoming
    1 upper incoming

    With three-position switch, circuit breaker, closing and breaking cable and bus, can close and break the rated current; the bus on both sides can expand. In the circuit breaker gas chamber, 3 female sockets are reserved to plug in/out the plug-in cable; the arrester, potential transformer and the unused sockets can be blocked. The cable has upper incoming or lower incoming. Can cancel or block the grounding switch.

    2

    图片3.jpg

    Sectional circuit breaker cabinet
    1 left link
    1 right link

    With three-position switch, combined the sectional circuit breaker cabinet, to sectionalize and link the bus; can cancel or block the grounding switch.

    3

    图片4.jpg

    Sectional insulation cabinet
    1 left link
    1 right link

    With three-position switch, combined with sectional circuit breaker cabinet, to sectionalize and link the bus; can cancel or block the grounding switch.

    Main technical parameters

    NO.

    Scheme

    Description

    Function

    4

    图片5.jpg

    Insulation upgraded cabinet
    1 lower incoming
    1 upper incoming

    With three-position switch, connect or insulate cable and bus; the bus on both sides can expand. Can cancel or block the grounding switch if grounding isn't required.

    5

    图片6.jpg

    Insulation cabinet

    With three-position switch, female socket is reserved in the gas tank to plug in the plug-in arrester and potential transformer.

    6

    图片7.jpg

    Metering cabinet

    With built-in current transformer and plug-in potential transformer, it can be combined with other functional units.

    7

    图片8.jpg

    Main bus grounding cabinet
    1 left link
    1 right link

    With grounding switch, ground the main bus; usually the bus on one side can expand to connect with the main buses of other functional units.

    Main technical parameters

    NO.

    Scheme

    Description

    Function

    8

    图片9.jpg

    Cable incoming/outgoing cabinet(for non-separable structure of gas tank)

    With three-position switch, circuit breaker, grounding and breaking cable and bus, can close or break the rated current, the bus on both sides can expand. On the bus side, can plug in/out the plug-in arrester or potential transformer and the unused sockets can be blocked. Can cancel or block the grounding switch if grounding isn’t required.

    9

    图片10.jpg

    Sectional+insulation cabinet
    -sectional circuit breaker cabinet and
    sectional insulation cabinet combined

    With three-position switch, circuit breaker and built-in current transformer, to sectionalize and link the bus. Can cancel or block the grounding switch if grounding isn’t required.

    Note: These functional modular units above are available for OEM partners.

    Model number: add rated voltage and branch bus rated current into the model number of the gas tank, if the main bus rated current and the branch bus rated current are different, indicate in the brackets.

    For example:

    XGN(DSR6) -12/1250: 12kV switchgear, branch bus, main bus rated current is 1250A;

    XGN(DSR6) -12/1250 (2500): 12kV switchgear, branch bus rated current is 1250A, main bus rated current is 2500A;

    Frequently Asked Questions
    What are the ambient temperature limits for this switchgear?
    The switchgear is designed to operate in ambient temperatures ranging from a lowest of -25°C to a highest of +50°C, with a 24-hour average temperature of ≤ 35°C.
    Can this equipment be installed at high altitudes?
    Yes, the switchgear is suitable for installations at altitudes ≤ 5000m. However, special attention must be paid when operating at altitudes exceeding 1000m.
    What type of insulation gas is used and what is its pressure level?
    The insulation gas used is SF6. The rated charge pressure is 0.14 M4pa (abs. 20°C) and the minimum charge pressure is 0.12 Mpa (abs. 20°C).
    What is the mechanical life expectancy of the main switches?
    The circuit breaker has a mechanical life of 10,000 operations, while the three-position switch has a mechanical life of 5,000 operations.
    How is the model number formulated when the main bus and branch bus currents differ?
    When the currents are different, the main bus rated current is indicated in brackets. For example: XGN(DSR6)-12/1250 (2500) indicates a 12kV switchgear with a branch bus rated current of 1250A and a main bus rated current of 2500A.
    Are these functional modular units customizable for OEM partners?
    Yes, all the described functional modular units (such as cable feeder cabinets, sectional circuit breakers, metering cabinets, etc.) are available for OEM partners.