Leave Your Message
24KV 630A Deadbreak T Rear Connector - China Quality Suppliers and Factory for Reliable Electrical Connections
Hot Products

24KV 630A Deadbreak T Rear Connector - China Quality Suppliers and Factory for Reliable Electrical Connections

,

Introducing our 24KV 630A European After Connector, designed for optimal performance and reliability. This high-quality connector is compatible with the T Fore connector and other back connectors, offering versatile branching options. Notably, it cannot be directly connected to the bushing, instead requiring a back protection cap to be placed over the end of the blanking cover. Our 630A European After Connector ensures a fully screened and submersible separable connection when paired with the appropriate bushing or plug, making it suitable for diverse applications. It is engineered to operate without minimum phase clearance requirements and can be mounted vertically, horizontally, or at any angle, providing ultimate flexibility. Enhance your electrical solutions with our built-in capacitive test point, allowing you to easily assess circuit status or install a fault indicator,

, As a leading manufacturer and supplier in China, we take pride in delivering outstanding products. Each package contains everything you need for installation, including the 630A European After Connector, an adaptor, conductor cable lug, connect lug, two head screws, silicone lubricant, clearing paper, an installation instruction sheet, and a quality certificate to assure you of our commitment to excellence.

,

    24KV 630A European After Connector

    General 630A European after connector can be use together with the T Fore connector and some other back connector, it can be provide more branches, and they can not together with the bushing directly, cover the back protection cap on the end of the blanking cover.

    Key Features

    • Provides a fully screened and fully submersible separable connection when mated with the proper bushing or plug.
    • Can be used under the circumstances.
    • Built-in capacitive test point to determine the circuit status or install a fault indicator.
    • No minimum phase clearance requirements.
    • Mounting can be vertical, horizontal, or any angle in between.
    24KV 630A European after connector
    Scope of Delivery
    630A European after connector Adaptor Conductor cable lug Connect lug Two head screw Silicone Lubricant Clearing Paper Installation Instruction Sheet Quality Certificate

    Technical Parameters (12/20 Cable Type)

    Reference No. Conductor cross section (mm²) Stretch range over insulation (mm) Cable Type Size of stress cone
    DR HJT-24/630-35 35 18.6 12/20 B
    DR HJT-24/630-50 50 20 12/20 B
    DR HJT-24/630-70 70 21.6 12/20 B
    DR HJT-24/630-95 95 23.2 12/20 C
    DR HJT-24/630-120 120 24.6 12/20 C
    DR HJT-24/630-150 150 26.2 12/20 C
    DR HJT-24/630-185 185 27.7 12/20 D
    DR HJT-24/630-240 240 30 12/20 D
    DR HJT-24/630-300 300 32.2 12/20 E
    DR HJT-24/630-400 400 35.4 12/20 E
    DR HJT-24/630-500 500 38.2 12/20 F
    DR HJT-24/630-630 630 41.5 12/20 F

    Technical Parameters (18/20 Cable Type)

    Reference No. Conductor cross section (mm²) Stretch range over insulation (mm) Cable Type Size of stress cone
    DR HJT-24/630-35 35 23.6 18/20 B
    DR HJT-24/630-50 50 25 18/20 B
    DR HJT-24/630-70 70 26.6 18/20 B
    DR HJT-24/630-95 95 28.2 18/20 C
    DR HJT-24/630-120 120 29.6 18/20 C
    DR HJT-24/630-150 150 31.2 18/20 C
    DR HJT-24/630-185 185 33.7 18/20 D
    DR HJT-24/630-240 240 35 18/20 D
    DR HJT-24/630-300 300 36.2 18/20 E
    DR HJT-24/630-400 400 40.4 18/20 E
    DR HJT-24/630-500 500 43.2 18/20 F
    DR HJT-24/630-630 630 46.5 18/20 F

    Frequently Asked Questions (FAQ)

    1. What is the application of the 24KV 630A European after connector?
    It is used together with the T Fore connector and other back connectors to provide more branches in medium voltage power systems. It cannot be connected directly with the bushing.
    2. Does the connector require a minimum phase clearance during installation?
    No, this European after connector does not have any minimum phase clearance requirements.
    3. What mounting angles are supported for this connector?
    The connector features flexible mounting options. It can be installed vertically, horizontally, or at any angle in between.
    4. How can I determine the circuit status of the connector?
    The connector is designed with a built-in capacitive test point, which allows you to easily determine the circuit status or install a fault indicator.
    5. What is included in the standard scope of delivery?
    The delivery package includes the 630A European after connector, adaptor, conductor cable lug, connect lug, two-head screw, silicone lubricant, clearing paper, installation instruction sheet, and a quality certificate.
    6. What types of cables are compatible with the DR HJT-24/630 series?
    It is compatible with 12/20 and 18/20 cable types, supporting conductor cross sections ranging from 35mm² up to 630mm² depending on the specific model.