24KV 630A Deadbreak T Rear Connector - China Factory Suppliers for Reliable Power Distribution Solutions
General 630A European after connector can be used together with the T Fore connector and some other back connector. It can provide more branches, and they cannot be connected together with the bushing directly. Cover the back protection cap on the end of the blanking cover.
Provides a fully screened and fully submersible separable connection when mated with the proper bushing or plug.
Can be used under all environmental circumstances.
Built-in capacitive test point to determine the circuit status or install a fault indicator.
No minimum phase clearance requirements for compact installations.
Mounting can be vertical, horizontal, or any angle in between.
| Reference No. | Conductor cross section (mm²) | Stretch range over insulation (mm) | Cable Type | Size of stress cone |
|---|---|---|---|---|
| DR HJT-24/630-35 | 35 | 18.6 | 12/20 | B |
| DR HJT-24/630-50 | 50 | 20 | 12/20 | B |
| DR HJT-24/630-70 | 70 | 21.6 | 12/20 | B |
| DR HJT-24/630-95 | 95 | 23.2 | 12/20 | C |
| DR HJT-24/630-120 | 120 | 24.6 | 12/20 | C |
| DR HJT-24/630-150 | 150 | 26.2 | 12/20 | C |
| DR HJT-24/630-185 | 185 | 27.7 | 12/20 | D |
| DR HJT-24/630-240 | 240 | 30 | 12/20 | D |
| DR HJT-24/630-300 | 300 | 32.2 | 12/20 | E |
| DR HJT-24/630-400 | 400 | 35.4 | 12/20 | E |
| DR HJT-24/630-500 | 500 | 38.2 | 12/20 | F |
| DR HJT-24/630-630 | 630 | 41.5 | 12/20 | F |
| Reference No. | Conductor cross section (mm²) | Stretch range over insulation (mm) | Cable Type | Size of stress cone |
|---|---|---|---|---|
| DR HJT-24/630-35 | 35 | 23.6 | 18/20 | B |
| DR HJT-24/630-50 | 50 | 25 | 18/20 | B |
| DR HJT-24/630-70 | 70 | 26.6 | 18/20 | B |
| DR HJT-24/630-95 | 95 | 28.2 | 18/20 | C |
| DR HJT-24/630-120 | 120 | 29.6 | 18/20 | C |
| DR HJT-24/630-150 | 150 | 31.2 | 18/20 | C |
| DR HJT-24/630-185 | 185 | 33.7 | 18/20 | D |
| DR HJT-24/630-240 | 240 | 35 | 18/20 | D |
| DR HJT-24/630-300 | 300 | 36.2 | 18/20 | E |
| DR HJT-24/630-400 | 400 | 40.4 | 18/20 | E |
| DR HJT-24/630-500 | 500 | 43.2 | 18/20 | F |
| DR HJT-24/630-630 | 630 | 46.5 | 18/20 | F |
1. Can the 630A European after connector be connected directly to the bushing?
No, they cannot be connected directly to the bushing. You must cover the back protection cap on the end of the blanking cover.
2. What components are included in the Scope of Delivery?
The package includes the 630A European after connector, Adaptor, Conductor cable lug, Connect lug, Two head screw, Silicone Lubricant, Clearing Paper, Installation Instruction Sheet, and a Quality Certificate.
3. What is the function of the built-in capacitive test point?
The built-in capacitive test point is used to determine the circuit status or to install a fault indicator directly onto the system.
4. Are there any mounting angle restrictions for this connector?
No, mounting is highly flexible and can be vertical, horizontal, or set at any angle in between depending on installation requirements.
5. Does this connector require minimum phase clearance?
No, there are no minimum phase clearance requirements, making it ideal for compact and space-constrained applications.
6. Can this connector be used with other connectors?
Yes, the general 630A European after connector can be used together with the T Fore connector and other back connectors to provide more branches.